Why is DE powder coming through my skimmer & main drain?

PSC Ep. 70: Why is DE powder coming through my skimmer & main drain?

In today’s episode of Poolside Chat, Rob and Matt tackle another common swimming pool question: 

Why is DE coming through my skimmer and main drain, when the pool pump shuts off?

The cause of DE plooms coming from the skimmers and main drains is different than the type that causes DE to flow from the return jets. DE leaking from the return jets can be caused from a hole in the DE grid, or crack in the manifold, something like that. DE leaking from your pump, skimmer or main drain is likely caused by an air leak. Basically, when the pump shuts off, air enters the system, or water drains out of the filter and back into the pool. That’s when you see the DE go back into the pool from the skimmer main drain. The leak could be on the pressure side or the suction side.

With the suction side, the main symptom is pump priming issues. That means, when you turn on the pump it takes longer to prime or does not prime at all without assistance. Another common symptom is are bubbles flowing from the return jets. To check for air leaks, from compromised PVC glued joints in your Tees, elbow joints, and valves. Read our guide on finding air leaks here: How to Identify and Correct Air Leaks.  We cover how to check your pump strainer lid o-ring, pump unions, and water levels.

Anything on the return side of the pump is considered the pressure-side. Common air leak culprits on the pressure-side are the pool filter’s air relief. If it is loose, you may see a water leak. Leaking unions on salt cells are a bad sign because when the pump shuts off again you are going to lose all that water out of your system. It’s going to run back into the pool.

click here to find your Replacement Filter Cartridges & Grids

2 thoughts on “PSC Ep. 70: Why is DE powder coming through my skimmer & main drain?

  1. I get DE leaking back through my skimmers and main suction whenever I turn on the water feature valve, after the pump is off. When switched to jets only (both utilize the same jandy valve) I have no DE leak. What could be the culprit? I have checked everything suction side and even pulled my filter grid and checked the standpipe and grids. No leak from the pressure relief valve and I had my backwash valve replaced. 35,000 gallon inground pool with FNS plus 60 and pentair 2 hp whisperflo.

    1. The water feature valve you are turning, or the pipe leading up to that valve has an air leak, causing the pump to lose prime once it is turned off. Or, if your water feature is above the pump when the pump turns off that water flushes backward through the system bringing the DE through the filter, pump and into the pool.

Leave a Reply

Your email address will not be published.

Recommended Resources

What should I use to test my pool water?

PSC Ep. 88: What should I use to test my pool water?

In today’s episode of Poolside Chat, Rob and Matt tackle another common swimming pool question:  What do you recommend I use...
Read Now
Do I need a fireman switch for my pool heater?

PSC Ep. 72: Do I need a fireman switch for my pool heater?

In today’s episode of Poolside Chat, Rob and Matt tackle another common swimming pool question:  Do new pool heaters require a...
Read Now
Can I repair my pool Equipment?

Can I Repair My Pool Equipment?

Now there’s a loaded question!  The quick answer is yes.  Many pool owners successfully tackle pool equipment repairs, the most common...
Read Now
Should I use flexible PVC for my pool plumbing?

PSC Ep. 48: Should I use flexible PVC for my pool plumbing?

In today’s episode of Poolside Chat, Rob and Matt tackle another common swimming pool question: Flex PVC vs Rigid PVC...
Read Now

Looking for pool parts?

Shop Motors Shop Filters Shop Pumps Shop Salt Systems Shop Lights Shop Cleaners
Copyright © 2024 INYOpools All rights reserved